LonMark Relay Control Terminal Unit

LonMark Relay Control Terminal Unit

Inquire now

LonMark Relay Control Terminal Unit

Click to enlarge image


Lighting Control Module Specification
  • Model : OCI-LCM (LonMark Relay Control Terminal Unit)
  • Dimensions : 350mm x 125mm x 80mm
  • Power Supply : AC/DC24V (Min 20mA / Max 2A)
  • CPU/Memory : FT3150 (10Mhz) / 32K Flash Memory
  • Transceiver : FTT-10A 78Kbps
  • Certification : CE, LonMark3.3
  • Communication : Link Powered TP (FTT-10A) (Not LPT-10)
  • I/O : 8 Channel Latch Relay Output (Up to 300V 20A Switching Load)
Programmable Switch Specification
  • Model : OCI-LPSx (LonMark Programmable Switch)
  • Dimensions : 72mm x 120mm(1CCT~4CCT), 120mm x 120mm(8CCT)
  • Power Supply : DC36V~DC48V, 25mA~30mA
  • CPU/Memory : FT3120 (1CCT~4CCT), FT-3150 (8CCT)
  • Transceiver : FTT-10A 78Kbps
  • Certification : CE, LonMark3.3
  • Communication : Link Powered TP (FTT-10A) (Not LPT-10)
Features (LCM / Program Switch)
  • User friendly, customer based Plug-In
  • LonMark3.3 Compliant
  • LED Indication from the feed back signal of each relay status
  • Easy Installation & Maintenance
  • In-built scheduler function up to 270 schedule steps
  • Easy, time saving functions for the individual, group, pattern lighting control applications
  • Manual relay on/off control using notch handle on each relay
  • Enable Switching Load up to 300V 20A
  • LonWorks Full 2-Way Remote Lighting Control Solution
  • Miscellaneous but powerful functions such as Debounce time, On/Off delay time, Lighting mode Selection, Default operation setting for each relay
LNS Based Plug-In

1) Programmable Switch Plug-In

2) Lamp Actuator Plug-In

3) Group/Pattern Setting-Up Plug-In

4) Schedule Setting-Up Plug-In

Application Design Consideration

1) When the number of Link Powered switch nodes are less than 20
and the total number of Lon Devices are not over 62;
- Don�t need to put an External Link Power Supply Unit on the LonWorks
but, use on-board SMPS(DC36V 30W) in the OCI-LCM as a Link Power Source

2) When the number of Link Powered switch nodes are over 20
and the total number of Lon Devices are less than 62;
- You need to put an External Link Power Supply Unit (DC36~DC48V) on the LonWorks Network as a Link Power Source

3) When the number of Link Powered switch nodes are less than 20 on channel1 and the number of Link Powered switch nodes are over 20 on channel2;
- You need to put an External Link Power Supply Unit (DC36~DC48V) on channel2 as a Link Power Source for switch nodes on channel2. Use Built-In SMPS(DC36V 30W) in the OCI-LCM as a Link Power Source for switch nodes on channel1

4) When you need to use 4-Wire LonWorks Switch (FTT-10A) nodes
supplied from other manufacturer with OCI-LCM lighting Control
Module instead of Full 2-Way Link Powered Switch node supplied from Orion C&I
- Don�t need to use any of Link Power Supply Unit, internally or externally

5) Consideration Factors when you choose a Link Power
Supply Unit (SMPS DC36~DC48V), Capability of SMPS is
defends on the number of Link Powered Switch on the network ;

  • Short Circuit Protection (Essential Function)
  • Built-In inrush current protection (Essential Function)
  • Over Voltage Protection (Recommended Function)
  • Built to meet FCC Class A (Recommended)
Shadow Object for Niagara Application
System Lay-Out for LNS Application
System Lay-Out for Niagara Application
What�s Different? How is Different?